COMPARISON OF PRESSURE AND STAFF WAVE GAGE RECORDS
PDF

Keywords

pressure gauge
staff wave gauge
gauge record

How to Cite

Esteva, D., & Harris, D. L. (1970). COMPARISON OF PRESSURE AND STAFF WAVE GAGE RECORDS. Coastal Engineering Proceedings, 1(12), 7. https://doi.org/10.9753/icce.v12.7

Abstract

Simultaneous records from two pressure gages located at different depths, a step-resistance relay gage, and a continuous-wire staff gage have been collected at Atlantic City, N J Spectra and cross-spectra are computed using the Fast Fourier Transform Algorithm (FFT) method proposed by Cooley and Tukey Individual harmonics of the pressure energy spectra are compensated for pressure attenuation according to classical theory Results indicate better agreement is obtained between the wave height and the spectra computed from the compensated pressure gages and those computed from the continuous-wire staff gage than between the two surface gages Values of coherences are near 98 in the energy-containing part of the spectrum, and are always larger for the pressure-continuous wire staff cases than for the two surface gages which are displaced from each other only 12 feet m the horizontal.
https://doi.org/10.9753/icce.v12.7
PDF
Authors retain copyright and grant the Proceedings right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this Proceedings.